RMS voltage
AC voltage is a sine wave, so we describe it with its RMS value, the steady DC voltage that heats a resistor the same. For a sine wave, peak = RMS × 1.414, so a 120 V outlet peaks near 170 V.
One number for a changing voltage
The voltage at an outlet is a sine wave: it climbs to a peak, falls through zero, swings negative and comes back, over and over. At any instant it has a different value, so which single number should we put on the label? The peak alone would overstate what the wave does most of the time, and the plain average of a full cycle is zero.
RMS: the DC that heats the same
Engineers answer with RMS, short for root mean square. Picture two identical heaters: one on a steady DC supply, one on the AC sine wave. The RMS value of the AC is the DC voltage that makes both heaters glow equally hot, delivering the same power. That's why "120 V" on an outlet means 120 V RMS: it does the same heating work as 120 V of steady DC.
Peak = RMS × 1.414
For a pure sine wave, the peak is always the RMS times the square root of 2, about 1.414. For a household outlet: 120 V × 1.414 = 169.7 V, about 170 V at the top of each swing (and about −170 V at the bottom).
Going the other way: × 0.707
To get from the peak to the RMS, divide by √2, which is the same as multiplying by about 0.707: RMS = peak × 0.707. When you set a multimeter to AC volts and read an outlet, the number it shows is RMS, not the peak.
Try it yourself
Use the same two ratios on other sine-wave voltages. A transformer rated 12 V AC (RMS) peaks at about 12 × 1.414 ≈ 17 V. The 230 V mains used in much of the world peaks at about 230 × 1.414 ≈ 325 V. Going back, a sine wave that peaks at 340 V has an RMS of about 340 × 0.707 ≈ 240 V.
Good to know
- RMS (root mean square) is the DC value that would dissipate the same heat in a resistor.
- For a pure sine wave:
RMS = peak × 0.707(1 ÷ √2) andpeak = RMS × 1.414(√2).120 × 1.414 = 169.7 V ≈ 170 V. - Mains voltage varies: in the US and Canada the standard range is about 114-126 V at the service (ANSI C84.1 / CSA CAN3-C235), so the peak varies too. Real waveforms are slightly flattened, so peaks can be a bit lower.
- These ratios hold only for sine waves; square and triangle waves have different ones.
- Many cheaper multimeters are "average-responding" and calibrated to show RMS correctly for sine waves only; "true-RMS" meters measure any waveform correctly. The video simplifies this to "multimeters show RMS on AC".
- The 230 V mains used in much of the world peaks around 325 V.
- Diagrams only: never probe an outlet for a demo, and leave wall wiring to a licensed electrician.
Answer to the comment question
A sine wave peaks at 100 volts. About what's its RMS voltage, to the nearest volt? About 71 volts. Multiply the peak by 0.707: 100 × 0.707 = 70.7 V, which rounds to 71 V.
Test your knowledge
Quick quiz: RMS voltage
4 multiple-choice questions. Pick one answer for each, then check how you did.
Sources
- All About Circuits, "Measurements of AC Magnitude": RMS as the DC heating equivalent; RMS = 0.707 × peak for sine waves; average-responding vs true-RMS meters
- OpenStax, "20.5 Alternating Current versus Direct Current": 120 V rms peaks at about 170 V
- HyperPhysics, "3 Phase Electric Wiring": a 120 V rms household circuit has a 170 V peak
Video transcript
Your outlet says 120 volts. So why does it actually peak around 170?
Because the voltage is a sine wave, always changing. So what single number should describe it?
Engineers use the voltage that heats a heater as much as steady DC would. That's RMS, root mean square.
For a sine wave, the peak is the RMS times about 1.41, the square root of 2.
120 times 1.414 is about 170 volts.
Going the other way, RMS is the peak times 0.707. Multimeters show RMS on AC.
A sine wave peaks at 100 volts. About what's its RMS voltage, to the nearest volt? Comment your answer below!
That's your byte.