Circuit Bytes · Episode 63 · Electronics · Power
"GFCI outlets"
A GFCI (ground fault circuit interrupter) outlet compares the current going out on the hot wire with the current coming back on the neutral. If about 5 milliamps go missing, for example leaking through a person to a wet floor, it cuts the power in a split second. That's why GFCIs are required near water, and why you should press TEST every month.
What the two buttons belong to
The outlet with TEST and RESET buttons in your bathroom or kitchen is a GFCI: a ground fault circuit interrupter. Its job is to watch for current going astray.
Out on hot = back on neutral
Electricity runs in a loop. Current goes out from the panel on the hot wire, through whatever is plugged in, and comes back on the neutral wire. Normally, every bit that goes out comes back: the two currents are equal.
A leak: less comes back
If current finds another way home, for example from a faulty hair dryer through a person to a wet floor, some of it never returns on the neutral. Now less comes back than went out, and that missing current is flowing somewhere it shouldn't, maybe through you.
About 5 milliamps → power off
Inside the GFCI, both wires pass through a sensor that acts like a balance. When about 5 milliamps go missing (a tiny amount), the balance tips and the GFCI opens the circuit in a split second, in as little as about 1/40 of a second. That's fast enough to help prevent a deadly shock.
Why they're near water
Water makes it much easier for current to leak through a person. That's why electrical codes require GFCI protection near water: bathrooms, kitchen counters, garages and outdoors (the exact list depends on your code edition and country).
TEST monthly, then RESET
Press TEST once a month: it should click off and the power at that outlet goes out. Press RESET to restore power. If it won't trip or won't reset, call a licensed electrician.
Safety first
These are diagrams only. Never open an outlet or touch wall wiring: leave it to a licensed electrician.
Try it yourself
Find the GFCI outlets in your home (look for the TEST and RESET buttons in the bathroom, kitchen, garage or outside). With an adult, plug in a small lamp, press TEST and watch it go dark, then press RESET and watch it come back. Some GFCIs also protect other outlets further along the same circuit: did any other outlet go dark too?
Good to know
- A GFCI compares the current on the hot and neutral wires, usually with a small current transformer that both wires pass through.
- US Class A GFCIs must not trip below about 4 milliamps and must trip by a little above 5, which is why "about 5 milliamps" is the usual rule of thumb. The bigger the leak, the faster they trip.
- A GFCI is not a breaker: it doesn't protect against overloads or short circuits (that's the breaker's job, see "Home wiring: hot, neutral, ground").
- It can't help if you touch hot and neutral at the same time with no leak to ground, because then the two currents still match.
- Many newer GFCIs test themselves, but pressing TEST monthly is still recommended.
- In many other countries the same idea is called an RCD (residual-current device).
- Diagrams only: never open an outlet, and leave wall wiring to a licensed electrician.
Answer to the comment question
Hot carries 2,000 milliamps. Neutral returns 1,994. How many milliamps are leaking? 6 milliamps. The leak is whatever goes out but doesn't come back: 2,000 mA − 1,994 mA = 6 mA. That's more than the roughly 5 milliamps a GFCI watches for, so it would trip and cut the power.
Test your knowledge
Quick quiz: "GFCI outlets"
4 multiple-choice questions. Pick one answer for each, then check how you did.
Sources
- US Consumer Product Safety Commission, "GFCI Fact Sheet": what a GFCI is, where it protects people, and testing it monthly
- OSHA Construction eTool, "Electrical Incidents: Ground-Fault Circuit Interrupters": a GFCI compares the current going out and coming back and trips on a difference of about 5 milliamps
- University of Washington Facilities, "Ground Fault Circuit Interrupters": how fast a GFCI cuts the power, in as little as 1/40 of a second
- Harvard Environmental Health and Safety, "Ground Fault Circuit Interrupter (GFCI) Fact Sheet": the trip threshold and where GFCIs are required
Video transcript
What do the two buttons on a bathroom outlet actually do?
That's a G F C I: a ground fault circuit interrupter. It watches for current going astray.
Normally, current out on the hot wire equals current back on neutral.
But if current leaks, say through a person to a wet floor, less comes back.
If about five milliamps go missing, it cuts the power in a split second, fast enough to help prevent a deadly shock.
That's why they're required near water: bathrooms, kitchens, garages, outdoors.
Press TEST monthly; it should click off. Press RESET to restore power. If it won't, call a licensed electrician.
Hot carries two thousand milliamps. Neutral returns one thousand nine hundred ninety-four. How many milliamps are leaking? Comment your answer below!
That's your byte.