Fuses and circuit breakers
Too much current overheats wires. A fuse is a thin metal strip in series that melts first and opens the circuit; a circuit breaker trips instead and can be reset.
Why too much current is dangerous
Current flowing through a wire heats it. Normal current keeps the wire warm at most, but too much current makes it hot. Hot enough, and the plastic insulation around the copper melts, which can start a fire. Fuses and breakers exist to cut the current before that happens. They protect the wiring and equipment, not people from shock: that is the job of GFCI outlets and grounding.
The fuse: the part that sacrifices itself
A fuse is a thin strip of metal placed in series with the circuit it protects, so all the current passes through it. The strip is the weakest point on purpose: when the current goes past the fuse's rating, the strip melts first and opens the circuit. The current stops, and the rest of the wiring stays safe. A blown fuse has done its job and gets replaced. Fuses are rated by current (amps) and by voltage.
The circuit breaker: trips, then resets
A circuit breaker does the same job, but instead of melting it trips: a switch inside snaps open. Once the problem is fixed you flip it back on. Common thermal-magnetic breakers have two ways to trip:
- a bimetallic strip, two metals bonded together that bend when they warm up, which catches a sustained overload;
- an electromagnet, which yanks the latch open on the huge, sudden current of a short circuit.
Ratings and watts
Many North American house circuits are rated 15 A at 120 V. Power is voltage times current, so the circuit can carry 120 V × 15 A = 1,800 W. Plug two 1,500 W space heaters into the same circuit and they need 3,000 W, well past the limit, so the breaker trips. Leave wall wiring to a licensed electrician.
Try it yourself
Find the wattage label on a kettle, hair dryer or space heater (it's printed on the base or the plug). Divide the watts by 120 V to get the amps it draws: a 1,200 W kettle draws 10 A. Then add up what usually runs on one circuit in your kitchen and compare it with 1,800 W for a 15 A circuit. Just read labels; never open a breaker panel or wall outlet.
Good to know
- A fuse is a conductive strip that melts under excess current; it is always in series with what it protects. Fuses are rated by current and by voltage.
- Thermal-magnetic breakers use a bimetallic strip for sustained overloads and an electromagnet for short circuits.
- Fuses and breakers protect wiring and equipment from overheating, not people from shock; GFCIs and grounding handle that.
15 A,120 Vbranch circuits are common in North America;20 Acircuits are also common in kitchens and bathrooms.- Continuous loads are usually kept to about 80% of the rating:
1,440 Won a15 Acircuit. - A breaker doesn't trip the instant a load passes its rating: a modest overload trips after a delay (its trip curve).
- Never replace a fuse with a higher-rated one: the wire would overheat before the fuse opens.
- Mains wiring is shown as diagrams only. Leave wall wiring to a licensed electrician.
Answer to the comment question
A 10-amp fuse protects a 12-volt circuit. What's the most power it allows, in watts? 120 watts. Power is voltage times current: 12 V × 10 A = 120 W.
Test your knowledge
Quick quiz: Fuses and circuit breakers
4 multiple-choice questions. Pick one answer for each, then check how you did.
Sources
- All About Circuits, "Fuses": a strip that melts under excess current, always in series; protects wiring, not people
- Control.com, "How Does a Circuit Breaker Work?": bimetallic strip for overloads, electromagnet for short circuits
- R&R Electric, "How Circuit Breakers Work": thermal-magnetic trip units
- Electrical Safety Foundation International (ESFI), "Home electrical safety": overloaded circuits; leave wiring to a licensed electrician
Video transcript
What part sacrifices itself so your house doesn't burn?
Too much current heats wires. Hot enough, and the insulation melts and can start a fire.
A fuse is a thin strip of metal placed in series. Too much current and it melts first, opening the circuit.
A circuit breaker does the same job, but it trips and can be reset. A heat-bending strip catches overloads; a magnet catches shorts.
Many North American house circuits are 15 amps at 120 volts.
That's 1,800 watts. Two 1,500-watt heaters need 3,000, so it trips. Leave wall wiring to a licensed electrician.
A 10-amp fuse protects a 12-volt circuit. What's the most power it allows, in watts? Comment your answer below!